Hexafluoroacetone is a colorless, nonflammablepoison gas. Musty odor. Shipped as a liquefied compressedgas. .Molecular weight= 163.00; Boiling point =- 28to - 26℃; FreezingMelting point= - 122℃; Relative vapordensity (air= 1)= 5.76; Vapor pressure = 5.8 atm at 25℃.Hazard Identification (based on NFPA-704 M Rating System):Health 3, Flammability 0, Reactivity 0. Reacts with water.
generally supplied as liquid under pressure
Hexafluoroacetone is a colorless, nonflamma ble poison gas. Musty odor. Shipped as a liquefied com pressed gas.
In the synthesis of polymer, pharmaceutical,
and agricultural chemicals; solvent for
polyamides, polyesters, and polyacetals; in the
synthesis of hexafluoroisopropanol
Hexafluoroacetone is a protecting and activatng reagent used in the synthesis of (S)-isoserine from (S)-malic acid. It is also an intermediate used to prepare hexafluorocarbinols as liver X receptor-α agonists.
Protecting and activating reagent in peptide chemistry; in synthesis of high performance fluoropolymers, pharmaceutical and agricultural chemicals; in 19F NMR. Solvent for polyamides, polyesters, polyacetals, polyols.
ChEBI: A ketone that is acetone in which all the methyl hydrogens are replaced by fluoro groups.
Canadian Journal of Chemistry, 33, p. 453, 1955
DOI: 10.1139/v55-055Organic Syntheses, Coll. Vol. 7, p. 251, 1990
Hexafluoroacetone is a colorless, toxic, and highly reactive gas. At ambient temperatures, Hexafluoroacetone is likely to generate a considerable amount of vapor. Hexafluoroacetone is an irritant to skin, eyes and mucous membranes and is toxic by ingestion, skin absorption, and inhalation. When heated to high temperatures Hexafluoroacetone emits toxic fluoride fumes. Prolonged exposure of the container to fire or intense heat may cause Hexafluoroacetone to violently rupture and rocket. Hexafluoroacetone is used in the production of other chemicals.
Hygroscopic (i.e., absorbs moisture from the air); reacts with moisture to form a highly acidic sesquihydrate. .
Hexafluoroacetone is incompatible with the following: Water, acids [Note: Hygroscopic (i.e., absorbs moisture from the air); reacts with moisture to form a highly acidic sesquihydrate.] .
Toxic by inhalation and skin absorption.
Reacts vigorously with water and other substances,
releasing considerable heat. Nonflammable.
TOXIC; may be fatal if inhaled, ingested or absorbed through skin. Vapors are extremely irritating and corrosive. Contact with gas or liquefied gas may cause burns, severe injury and/or frostbite. Fire will produce irritating, corrosive and/or toxic gases. Runoff from fire control may cause pollution.
Some may burn but none ignite readily. Vapors from liquefied gas are initially heavier than air and spread along ground. Some of these materials may react violently with water. Cylinders exposed to fire may vent and release toxic and/or corrosive gas through pressure relief devices. Containers may explode when heated. Ruptured cylinders may rocket.
Hexafluoroacetone is used as a chemi cal intermediate. A gas at room temperature, it forms vari ous hydrates with water which are used as solvents for
resins and polymers. Other derivatives are used to make
water repellent coatings for textiles and also to produce
polymers.
If this chemical gets into the eyes, remove anycontact lenses at once and irri gate immediately for at least15 min, occasionally lifting upper and lower lids. Seekmedical attention immediately. If this chemical contacts theskin, remove contaminated clothing and wash immediatelywith soap and water. Seek medical attention immediately. Ifthis chemical has been inhaled,remove from exposure,begin rescue breathing (using universal precautions, includ-ing resuscitation mask) if breathing has stopped and CPR ifheart action has stopped. Transfer promptly to a medicalfacility. When this chemical has been swallowed, get medi-cal attention. Give large quantities of water and inducevomiting. Do not make an unconscious person vomit.Medical observation is recommended for 24- -48 h afterbreathing overexposure, as pulmonary edemamay bedelayed. As first aid for pulmonary edema, a doctor orauthorized paramedic may consider administering a cortico-steroid spray. If frostbite has occurred, seek medical atten-tion immediately; do NOT rub the affected areas or flushthem with water. In order to prevent further tissue damage,do NOT attempt to remove frozen clothing from frostbittenareas. If frostbite has NOT occurred, immediately andthoroughly wash contaminated skin with soap and water.
(1) Color Code- White stripe: Contact Hazard;Store separately; not compatible with materials in solidwhite category. (2) Color Code- Blue (poison gas): HealthHazard/Poison: Store in a secure poison location. Prior toworking with this chemical youshould be trained on itsproper handling and storage. Store in tightly closed contain-ers in a cool, well-ventilatedarea away from direct sunlight,water,heat, reducing agents, nitrates, and nitric acid.Procedures for the handling, use, and storage of cylindersshould be in compliance with OSHA 1910.101and1910.169, as with the recommendations of the CompressedGas A ssociation.
UN2420 Hexafluoroacetone, Hazard Class: 2.3;
Labels: 2.3-Poisonous gas, 8-Corrosive material, Inhalation
Hazard Zone B. Cylinders must be transported in a secure
upright position, in a well-ventilated truck. Protect cylinder
and labels from physical damage. The owner of the com pressed gas cylinder is the only entity allowed by federal
law (49CFR) to transport and refill them. It is a violation
of transportation regulations to refill compressed gas cylin ders without the express written permission of the owner.
Dehydrate hexafluoroacetone by passing the vapours over P2O5. Ethylene is removed by passing the dried vapours through a tube containing Pyrex glass wool moistened with conc H2SO4. Further purification is by low temperature distillation using Warde-Le Roy stills. Store it in the dark at -78o. [Holmes & Kutschke Trans Faraday Soc 58 333 1962, Beilstein 1 IV 3215.]
Reacts with water, oxidizers, strong
acids. Hygroscopic (i.e., absorbs moisture from the air);
reacts with moisture to form a highly acidic sesquihydrate
and considerable heat.
Return refillable compressed
gas cylinders to supplier. Nonrefillable cylinders should be
disposed of in accordance with local, state and federal
regulations. Allow remaining gas to vent slowly into
atmosphere in an unconfined area or exhaust hood.
Refillable-type cylinders should be returned to original sup plier with any valve caps and outlet plugs secured and
valve protection caps in place.