简单介绍: 
Fluorescent dyes absorb light at certain wavelengths and in turn emit their fluorescence energy at a higher wavelength. Each dye has a distinct emission spectrum, which can be exploited for multicolor analysis. eBioscience antibodies are available conjugated to a wide variety of fluorochromes. 

The tables below lists the properties of the most commonly used fluorochromes in flow cytometry. The eBioscience product number is the prefix used in our catalog numbering system to indicate the corresponding formats of our antibodies. We are continually developing new fluorochrome conjugated antibodies for both flow cytometry and microscopy. Please feel free to contact us at tech@ebioscience.com for more information!

 

产品编号

荧光染料

激发波长(nm)

发射波长 (nm)

荧光强度

使用说明

 

 

 

 

1=最低荧光强度

 

 

 

 

 

5=最高荧光强度

 

11

FITC (Fluorescein isothiocyanate)

488

518

3

Detected in FL1 channel on most instruments; also a good choice for fluorescence microscopy

53

Alexa Fluor® 488

488

519

3

Detected in FL1 channel on most instruments; photostable; an excellent choice for fluorescence microscopy

12

R-PE 

488

575

5

Detected in FL2 channel on most instruments; very high quantum yield (ideal for detection of low density antigens); subject to photobleaching.

(R-Phycoerythrin)

-

PE-Texas Red

488

615

3

Detected in FL3 on single laser instruments

-

PE-Alexa Fluor®610

488

628

3

This alternative to PE-Texas Red has less overlap with PE due to its 628nm emission wavelength and is less subject to Fc mediated binding than PE-Cy5.

15

PE-Cy5

488

670

4

Detected in FL3 or FL4 on most instruments; tandem dye, resonance energy transfer from PE molecule to the cyanine dye Cy5; when used with APC on dual laser machines, needs a cytometer capable of interlaser compensation. See PE-Cy5.5 for dual laser instruments

35

PE-Cy5.5

488

690

3

Detected in FL3 or FL4 on most instruments; tandem dye, resonance energy transfer from PE molecule to cyanine dye Cy5.5; when used with APC on dual laser machines, needs a cytometer capable of interlaser compensation. Better choice for dual laser instruments than PE-Cy5.

45

PerCP-Cy5.5

488

690

3

Detected in FL3 or FL4 on most instruments; tandem dye, resonance energy transfer from PerCP molecule to cyanine dye Cy5.5; when used with APC on dual laser machines, needs a cytometer capable of inter-laser compensation. Better choice for dual laser instruments than PE-tandems as a result of its exceptionally large stokes shift.

25

PE-Cy7

488

760

3

Detected in appropriate channel based on filter set arrangement of the instrument; tandem dye, resonance energy transfer from PE molecule to cyanine dye Cy7; minimal cross-beam compensation required when used simultaneously

-

7-AAD

488

647

 

Detected in FL3 channel on most instruments; binds selectively to GC regions of DNA; used as a viability dye to discriminate between viable and non-viable cells

-

Propidium Iodide (PI)

488

617

 

Detected in FL2 and FL3 channels on most instruments; a DNA intercalating dye; used as a viability dye to discriminate between viable and nonviable cells

Table 1: Fluorescent Dyes for Flow Cytometric Analysis - 488nm Excitation

 

 