Home > 2-Isocyanatoethyl methacrylate > 2-Isocyanatoethyl methacrylate(30674-80-7)
2-Isocyanatoethyl methacrylate(30674-80-7)
Supplier Product Identification
Physical and Chemical Properties
First Aid Measures
Handling and Storage
Hazards Identification
Exposure Controls/Personal Protection
Fire Fighting Measures
Accidental Release Measures
Stability and Reactivity
Transport Information
Product Identification
Product Name
2-Isocyanatoethyl methacrylate
2-Isocyanatoethyl methacrylate
Synonyms
2-(Methacryloyloxy)ethyl isocyanate
2-Isocyanatoethyl 2-methylprop-2-enoate
2-Isocyanatoethyl methacrylate
2-Propenoic acid, 2-methyl-, 2-isocyanatoethyl ester
Isocyanic acid, 2-hydroxyethyl ester methacrylate (ester)
Methacrylic acid, 2-isocyanatoethyl ester
2-(Methacryloyloxy)ethyl isocyanate
2-Isocyanatoethyl 2-methylprop-2-enoate
2-Isocyanatoethyl methacrylate
2-Propenoic acid, 2-methyl-, 2-isocyanatoethyl ester
Isocyanic acid, 2-hydroxyethyl ester methacrylate (ester)
Methacrylic acid, 2-isocyanatoethyl ester
CAS
30674-80-7
30674-80-7
Formula
C7H9NO3
C7H9NO3
Molecular Weight
155.16999999999999
155.16999999999999
EINECS
250-284-7
250-284-7
RTECS
OZ4950000
OZ4950000
RTECS Class
Reproductive Effector
Reproductive Effector
Beilstein/Gmelin
1768533
1768533
Beilstein Reference
4-04-00-01555
4-04-00-01555
Physical and Chemical Properties
Solubility in water
Insoluble
Insoluble
Boiling Point
219
219
Vapor Pressure
0.12 (25 C)
0.12 (25 C)
Partition Coefficient
2.27
2.27
Heat Of Vaporization
45.5 kJ/mol
45.5 kJ/mol
Refractive Index
1.4496 (20 C)
1.4496 (20 C)
First Aid Measures
Ingestion
Due to the irritant nature of isocyanates, vomiting is not advised. Consider after ingestion of a potentially life-threatening amount of poison if it can be performed soon after ingestion (generally within 1 hour). Activated charcoal: administer charcoal as a slurry (240 ml water/30 g charcoal). Usual dose: 25 to 100 g in adults/adolescents. Monitor patient for respiratory distress. If a cough or difficulty in breathing develops, evaluate for respiratory tract irritation, bronchitis and pneumonia. Allergic reaction - sensitized individuals should be cautioned to avoid further exposure, as serious allergic reactions may result.
Due to the irritant nature of isocyanates, vomiting is not advised. Consider after ingestion of a potentially life-threatening amount of poison if it can be performed soon after ingestion (generally within 1 hour). Activated charcoal: administer charcoal as a slurry (240 ml water/30 g charcoal). Usual dose: 25 to 100 g in adults/adolescents. Monitor patient for respiratory distress. If a cough or difficulty in breathing develops, evaluate for respiratory tract irritation, bronchitis and pneumonia. Allergic reaction - sensitized individuals should be cautioned to avoid further exposure, as serious allergic reactions may result.
Inhalation
Move patient to fresh air. Monitor for respiratory distress. If cough or difficulty breathing develops, evaluate for respiratory tract irritation, bronchitis, or pneumonitis. Administer oxygen and assist ventilation as required. Treat bronchospasm with beta2 agonist and corticosteroid aerosols.
Move patient to fresh air. Monitor for respiratory distress. If cough or difficulty breathing develops, evaluate for respiratory tract irritation, bronchitis, or pneumonitis. Administer oxygen and assist ventilation as required. Treat bronchospasm with beta2 agonist and corticosteroid aerosols.
Skin
Remove contaminated clothing and wash exposed area thoroughly with soap and water. A physician should examine the area if irritation or pain persists. Treat dermal irritation or burns with standard topical therapy. Patients developing dermal hypersensitivity reactions may require treatment with systemic or topical corticosteroids or antihistamines.
Remove contaminated clothing and wash exposed area thoroughly with soap and water. A physician should examine the area if irritation or pain persists. Treat dermal irritation or burns with standard topical therapy. Patients developing dermal hypersensitivity reactions may require treatment with systemic or topical corticosteroids or antihistamines.
Eyes
Irrigate exposed eyes with copious amounts of tepid water for at least 15 minutes. If irritation, pain, swelling, lacrimation, or photophobia persist, the patient should be seen in a health care facility.
Irrigate exposed eyes with copious amounts of tepid water for at least 15 minutes. If irritation, pain, swelling, lacrimation, or photophobia persist, the patient should be seen in a health care facility.
Handling and Storage
Storage
Keep in a cool, dry, dark location in a tightly sealed container or cylinder. Keep away from incompatible materials, ignition sources and untrained individuals. Secure and label area. Protect containers/cylinders from physical damage.
Keep in a cool, dry, dark location in a tightly sealed container or cylinder. Keep away from incompatible materials, ignition sources and untrained individuals. Secure and label area. Protect containers/cylinders from physical damage.
Handling
All chemicals should be considered hazardous. Avoid direct physical contact. Use appropriate, approved safety equipment. Untrained individuals should not handle this chemical or its container. Handling should occur in a chemical fume hood.
All chemicals should be considered hazardous. Avoid direct physical contact. Use appropriate, approved safety equipment. Untrained individuals should not handle this chemical or its container. Handling should occur in a chemical fume hood.
Hazards Identification
Ingestion
Inhalation of vapor or aerosol may produce vomiting and abdominal pain. Epigastric and substernal pain may be secondary to the paroxysmal or persistent cough associated with inhalation.
Inhalation of vapor or aerosol may produce vomiting and abdominal pain. Epigastric and substernal pain may be secondary to the paroxysmal or persistent cough associated with inhalation.
Inhalation
Burning or irritation of the nose and throat, cough, laryngitis, chest pain, and asthmatic syndrome (chemical bronchitis with severe bronchospasm) sensation of oppression or constriction of the chest, bronchitis, emphysema and cor pulmonale may occur.
Burning or irritation of the nose and throat, cough, laryngitis, chest pain, and asthmatic syndrome (chemical bronchitis with severe bronchospasm) sensation of oppression or constriction of the chest, bronchitis, emphysema and cor pulmonale may occur.
Skin
Irritation and inflammation are common with isocyanates. Isocyanates may burn the skin.
Irritation and inflammation are common with isocyanates. Isocyanates may burn the skin.
Eyes
See Inhalation.
See Inhalation.
Hazards
Vapors form explosive mixtures with air: indoors, outdoors, and sewers explosion hazards. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapors may travel to source of ignition and flash back. Substance will react with water (some violently) releasing flammable, toxic or corrosive gases and runoff.
Vapors form explosive mixtures with air: indoors, outdoors, and sewers explosion hazards. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapors may travel to source of ignition and flash back. Substance will react with water (some violently) releasing flammable, toxic or corrosive gases and runoff.
UN (DOT)
3080
3080
Exposure Controls/Personal Protection
Personal Protection
Wear appropriate protective gloves, clothing and goggles.
Wear appropriate protective gloves, clothing and goggles.
Respirators
Wear positive pressure self-contained breathing apparatus (SCBA).
Wear positive pressure self-contained breathing apparatus (SCBA).
Fire Fighting Measures
Flash Point
93
93
Fire Fighting
(Non-Specific -- Isocyanates and Solutions, n.o.s. (Flammable, Poisonous)) Keep unnecessary people away; isolate hazard area and deny entry. Stay upwind; keep out of low areas. Ventilate closed spaces before entering them. Wear positive pressure breathing apparatus and special protective clothing. Move container from fire area if you can do it without risk. Cool containers that are exposed to flames with water from the side until well after fire is out. Fight fire from maximum distance. Dike fire control water for later disposal; do not scatter the material.(Non-Specific -- Isocyanates and solutions, n.o.s. (Flammable, Poisonous)) Small fires: dry chemical, carbon dioxide, water spray, or foam. Large fires: water spray, fog, or foam.
(Non-Specific -- Isocyanates and Solutions, n.o.s. (Flammable, Poisonous)) Keep unnecessary people away; isolate hazard area and deny entry. Stay upwind; keep out of low areas. Ventilate closed spaces before entering them. Wear positive pressure breathing apparatus and special protective clothing. Move container from fire area if you can do it without risk. Cool containers that are exposed to flames with water from the side until well after fire is out. Fight fire from maximum distance. Dike fire control water for later disposal; do not scatter the material.(Non-Specific -- Isocyanates and solutions, n.o.s. (Flammable, Poisonous)) Small fires: dry chemical, carbon dioxide, water spray, or foam. Large fires: water spray, fog, or foam.
Fire Potential
HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames.
HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames.
Accidental Release Measures
Small spills/leaks
(Non-Specific -- Isocyanates and Solutions, n.o.s. (Flammable, Poisonous)) Keep unnecessary people away; isolate hazard area and deny entry. Stay upwind; keep out of low areas. Ventilate closed spaces before entering them. Shut off ignition sources; no flares, smoking or flames in hazard area. Do not touch spilled material; stop leak if you can do so without risk. Use water spray to reduce vapors. Small spills: absorb with sand or other noncombustible absorbent material and place into containers for later disposal. Small dry spills: with clean shovel place material into clean, dry container and cover; move containers from spill area. Large spills: dike far ahead of spill for later disposal.
(Non-Specific -- Isocyanates and Solutions, n.o.s. (Flammable, Poisonous)) Keep unnecessary people away; isolate hazard area and deny entry. Stay upwind; keep out of low areas. Ventilate closed spaces before entering them. Shut off ignition sources; no flares, smoking or flames in hazard area. Do not touch spilled material; stop leak if you can do so without risk. Use water spray to reduce vapors. Small spills: absorb with sand or other noncombustible absorbent material and place into containers for later disposal. Small dry spills: with clean shovel place material into clean, dry container and cover; move containers from spill area. Large spills: dike far ahead of spill for later disposal.
Stability and Reactivity
Incompatibilities
Incompatible with many classes of compounds, reacting exothermically to release toxic gases Reactions with amines, aldehydes, alcohols, alkali metals, ketones, mercaptans, strong oxidizers, hydrides, phenols, and peroxides can cause vigorous releases of heat.
Incompatible with many classes of compounds, reacting exothermically to release toxic gases Reactions with amines, aldehydes, alcohols, alkali metals, ketones, mercaptans, strong oxidizers, hydrides, phenols, and peroxides can cause vigorous releases of heat.
Stability
No data.
No data.
Combustion Products
Fire will produce irritating, corrosive and/or toxic gases.
Fire will produce irritating, corrosive and/or toxic gases.
Transport Information
UN Number
3080
3080
Hazard Class
6.1
6.1
Packing Group
II
II
Contact
More
- Company Name:Hubei yongkuo Technology Co., Ltd
- Tel:027-59223108 15972152991
- Fax:027-59223108
- WebSite:https://www.chemicalbook.com/ShowSupplierProductsList1025246/0.htm
- Company Name:Hubei Wande Chemical Co., Ltd
- Tel:027-59210159 15377098680
- Fax:027-59210159
- WebSite:http://www.wande-chem.com/
- Company Name:Wuhan lanabai Pharmaceutical Chemical Co., Ltd
- Tel: 15307151931
- Fax:QQ-2355680
- WebSite:http://www.lullabypharm-chem.com
- Company Name:Wuhan Rongcan Biotechnology Co., Ltd
- Tel: 18327024450
- Fax:183-27024450
- WebSite:https://www.chemicalbook.com/ShowSupplierProductsList707052/0.htm
- Company Name:J & K SCIENTIFIC LTD.
- Tel:010-82848833 400-666-7788
- Fax:86-10-82849933
- WebSite:http://www.jkchemical.com