Home > N,N-Dimethylaminoethyl acrylate > N,N-Dimethylaminoethyl acrylate(2439-35-2)
N,N-Dimethylaminoethyl acrylate(2439-35-2)
Supplier Product Identification
Physical and Chemical Properties
First Aid Measures
Handling and Storage
Hazards Identification
Exposure Controls/Personal Protection
Fire Fighting Measures
Accidental Release Measures
Stability and Reactivity
Transport Information
Product Identification
Product Name
N,N-Dimethylaminoethyl acrylate
N,N-Dimethylaminoethyl acrylate
Synonyms
2-(Dimethylamino)ethyl acrylate
2-(Dimethylamino)ethyl acrylate
CAS
2439-35-2
2439-35-2
Formula
C7H13NO2
C7H13NO2
Molecular Weight
143.21
143.21
EINECS
219-460-0
219-460-0
RTECS
AS8578000
AS8578000
RTECS Class
Mutagen
Mutagen
Beilstein/Gmelin
1099119
1099119
Beilstein Reference
4-04-00-01431
4-04-00-01431
Physical and Chemical Properties
Appearance
A colorless to light yellow liquid with an acrid odor.
A colorless to light yellow liquid with an acrid odor.
Solubility in water
Very soluble
Very soluble
Melting Point
<-60
<-60
Boiling Point
177
177
Vapor Pressure
1 (25 C)
1 (25 C)
Density
0.9406 g/cm3 (20 C)
0.9406 g/cm3 (20 C)
pKa/pKb
5.79 (pKb)
5.79 (pKb)
Partition Coefficient
.95
.95
Heat Of Vaporization
41.4 kJ/mol
41.4 kJ/mol
Refractive Index
1.4372 (20 C)
1.4372 (20 C)
First Aid Measures
Ingestion
DO NOT INDUCE VOMITING. Corrosive chemicals will destroy the membranes of the mouth, throat, and esophagus and, in addition, have a high risk of being aspirated into the victim's lungs during vomiting which increases the medical problems. If the victim is conscious and not convulsing, give 1 or 2 glasses of water to dilute the chemical and IMMEDIATELY call a hospital or poison control center. IMMEDIATELY transport the victim to a hospital. If the victim is convulsing or unconscious, do not give anything by mouth, ensure that the victim's airway is open and lay the victim on his/her side with the head lower than the body. DO NOT INDUCE VOMITING. Transport the victim IMMEDIATELY to a hospital.
DO NOT INDUCE VOMITING. Corrosive chemicals will destroy the membranes of the mouth, throat, and esophagus and, in addition, have a high risk of being aspirated into the victim's lungs during vomiting which increases the medical problems. If the victim is conscious and not convulsing, give 1 or 2 glasses of water to dilute the chemical and IMMEDIATELY call a hospital or poison control center. IMMEDIATELY transport the victim to a hospital. If the victim is convulsing or unconscious, do not give anything by mouth, ensure that the victim's airway is open and lay the victim on his/her side with the head lower than the body. DO NOT INDUCE VOMITING. Transport the victim IMMEDIATELY to a hospital.
Inhalation
IMMEDIATELY leave the contaminated area; take deep breaths of fresh air. If symptoms (such as wheezing, coughing, shortness of breath, or burning in the mouth, throat, or chest) develop, call a physician and be prepared to transport the victim to a hospital. Provide proper respiratory protection to rescuers entering an unknown atmosphere. Whenever possible, Self-Contained Breathing Apparatus (SCBA) should be used.
IMMEDIATELY leave the contaminated area; take deep breaths of fresh air. If symptoms (such as wheezing, coughing, shortness of breath, or burning in the mouth, throat, or chest) develop, call a physician and be prepared to transport the victim to a hospital. Provide proper respiratory protection to rescuers entering an unknown atmosphere. Whenever possible, Self-Contained Breathing Apparatus (SCBA) should be used.
Skin
IMMEDIATELY flood affected skin with water while removing and isolating all contaminated clothing. Gently wash all affected skin areas thoroughly with soap and water. IMMEDIATELY call a hospital or poison control center even if no symptoms (such as redness or irritation) develop. IMMEDIATELY transport the victim to a hospital for treatment after washing the affected areas.
IMMEDIATELY flood affected skin with water while removing and isolating all contaminated clothing. Gently wash all affected skin areas thoroughly with soap and water. IMMEDIATELY call a hospital or poison control center even if no symptoms (such as redness or irritation) develop. IMMEDIATELY transport the victim to a hospital for treatment after washing the affected areas.
Eyes
First check the victim for contact lenses and remove if present. Flush victim's eyes with water or normal saline solution for 20 to 30 minutes while simultaneously calling a hospital or poison control center. Do not put any ointments, oils, or medication in the victim's eyes without specific instructions from a physician. IMMEDIATELY transport the victim after flushing eyes to a hospital even if no symptoms (such as redness or irritation) develop.
First check the victim for contact lenses and remove if present. Flush victim's eyes with water or normal saline solution for 20 to 30 minutes while simultaneously calling a hospital or poison control center. Do not put any ointments, oils, or medication in the victim's eyes without specific instructions from a physician. IMMEDIATELY transport the victim after flushing eyes to a hospital even if no symptoms (such as redness or irritation) develop.
Handling and Storage
Storage
Keep in a cool, dry, dark location in a tightly sealed container or cylinder. Keep away from incompatible materials, ignition sources and untrained individuals. Secure and label area. Protect containers/cylinders from physical damage.
Keep in a cool, dry, dark location in a tightly sealed container or cylinder. Keep away from incompatible materials, ignition sources and untrained individuals. Secure and label area. Protect containers/cylinders from physical damage.
Handling
All chemicals should be considered hazardous. Avoid direct physical contact. Use appropriate, approved safety equipment. Untrained individuals should not handle this chemical or its container. Handling should occur in a chemical fume hood.
All chemicals should be considered hazardous. Avoid direct physical contact. Use appropriate, approved safety equipment. Untrained individuals should not handle this chemical or its container. Handling should occur in a chemical fume hood.
Hazards Identification
Inhalation
Highly toxic, may be fatal if inhaled, swallowed or absorbed through skin. Effects of contact or inhalation may be delayed.
Highly toxic, may be fatal if inhaled, swallowed or absorbed through skin. Effects of contact or inhalation may be delayed.
Skin
Contact with molten substance may cause severe burns to skin and eyes. Avoid any skin contact.
Contact with molten substance may cause severe burns to skin and eyes. Avoid any skin contact.
Eyes
See Skin.
See Skin.
Hazards
Containers may explode when heated. Runoff may pollute waterways. Substance may be transported in a molten form.
Containers may explode when heated. Runoff may pollute waterways. Substance may be transported in a molten form.
EC Risk Phrase
R 21/22 26 34
R 21/22 26 34
EC Safety Phrase
S 26 28 36/37/39 45
S 26 28 36/37/39 45
UN (DOT)
3302
3302
Exposure Controls/Personal Protection
Personal Protection
If Tyvek-type disposable protective clothing is not worn during handling of this chemical, wear disposable Tyvek-type sleeves taped to your gloves.
If Tyvek-type disposable protective clothing is not worn during handling of this chemical, wear disposable Tyvek-type sleeves taped to your gloves.
Respirators
When working with this chemical, wear a NIOSH-approved full face chemical cartridge respirator equipped with the appropriate organic vapor cartridges. If that is not available, a half face respirator similarly equipped plus airtight goggles can be substituted. However, please note that half face respirators provide a substantially lower level of protection than do full face respirators.
When working with this chemical, wear a NIOSH-approved full face chemical cartridge respirator equipped with the appropriate organic vapor cartridges. If that is not available, a half face respirator similarly equipped plus airtight goggles can be substituted. However, please note that half face respirators provide a substantially lower level of protection than do full face respirators.
Exposure Effects
The toxological properties of this substance have not been fully investigated.
The toxological properties of this substance have not been fully investigated.
Fire Fighting Measures
Flash Point
58
58
Fire Fighting
Use water in flooding quantities as fog. Use foam, dry chemical, or carbon dioxide. Cool all affected containers with flooding quantities of water. Apply water from as far a distance as possible. Keep run-off water out of sewers and water sources.
Use water in flooding quantities as fog. Use foam, dry chemical, or carbon dioxide. Cool all affected containers with flooding quantities of water. Apply water from as far a distance as possible. Keep run-off water out of sewers and water sources.
Fire Potential
This chemical is flammable.
This chemical is flammable.
Accidental Release Measures
Small spills/leaks
Keep material out of water sources and sewers. Use water spray to knock-down vapors. Land spill: Dig a pit, pond, lagoon, holding area to contain liquid or solid material. Dike surface flow using soil, sand bags, foamed polyurethane, or foamed concrete. Absorb bulk liquid with fly ash, cement powder, or commercial sorbents. Water spill: Use natural barriers or oil spill control booms to limit spill travel. Remove trapped material with suction hoses.
Keep material out of water sources and sewers. Use water spray to knock-down vapors. Land spill: Dig a pit, pond, lagoon, holding area to contain liquid or solid material. Dike surface flow using soil, sand bags, foamed polyurethane, or foamed concrete. Absorb bulk liquid with fly ash, cement powder, or commercial sorbents. Water spill: Use natural barriers or oil spill control booms to limit spill travel. Remove trapped material with suction hoses.
Stability and Reactivity
Incompatibilities
Incompatible with isocyanates, halogenated organics, peroxides, phenols (acidic), epoxides, anhydrides, and acid halides Flammable gaseous hydrogen is generated in combination with strong reducing agents, such as hydrides Strong oxidizing acids may cause a vigorous reaction that is sufficiently exothermic to ignite the reaction products.
Incompatible with isocyanates, halogenated organics, peroxides, phenols (acidic), epoxides, anhydrides, and acid halides Flammable gaseous hydrogen is generated in combination with strong reducing agents, such as hydrides Strong oxidizing acids may cause a vigorous reaction that is sufficiently exothermic to ignite the reaction products.
Stability
No data.
No data.
Combustion Products
Fire may produce irritating, corrosive and/or toxic gases.
Fire may produce irritating, corrosive and/or toxic gases.
Transport Information
UN Number
3302
3302
Hazard Class
6.1
6.1
Packing Group
II
II
Contact
More
- Company Name:Qingdao RENAS Polymer Material Co.,Ltd.
- Tel:0532-0532-86867058 18562606086
- Fax:0532-86867058
- WebSite:http://www.qdrenas.com
- Company Name:Hubei Honghan Biotech Co., Ltd
- Tel:0719-0719-7199239 15675290733
- Fax:
- WebSite:https://www.chemicalbook.com/ShowSupplierProductsList1901393/0.htm
- Company Name:J & K SCIENTIFIC LTD.
- Tel:010-82848833 400-666-7788
- Fax:86-10-82849933
- WebSite:http://www.jkchemical.com
- Company Name:Meryer (Shanghai) Chemical Technology Co., Ltd.
- Tel:021-61259108 18621169109
- Fax:86-21-61259102
- WebSite:https://www.meryer.com/cn/index/
- Company Name:Alfa Aesar
- Tel:400-6106006
- Fax:021-67582001/03/05
- WebSite:http://chemicals.thermofisher.cn