Supplier Product Identification Physical and Chemical Properties First Aid Measures Hazards Identification Exposure Controls/Personal Protection Fire Fighting Measures Accidental Release Measures Transport Information Stability and Reactivity
Home > Diethoxymethylsilane > Diethoxymethylsilane(2031-62-1)

Diethoxymethylsilane(2031-62-1)

Supplier Product Identification Physical and Chemical Properties First Aid Measures Hazards Identification Exposure Controls/Personal Protection Fire Fighting Measures Accidental Release Measures Transport Information Stability and Reactivity

Product Identification

Product Name
Diethoxymethylsilane
Synonyms
Methyldiethoxysilane
CAS
2031-62-1
Formula
C5H14O2Si
Molecular Weight
134.25
EINECS
217-982-3
Beilstein/Gmelin
1733975
Beilstein Reference
4-04-00-04095

Physical and Chemical Properties

Boiling Point
95
Density
0.829 g/cm3 (25 C)
Refractive Index
1.38 (20 C)

First Aid Measures

Ingestion
Seek medical assistance.
Inhalation
Move victim to fresh air. Apply artificial respiration if victim is not breathing. Administer oxygen if breathing is difficult.
Skin
Remove and isolate contaminated clothing and shoes. Wash skin with soap and water. Flush with running water for at least 20 minutes
Eyes
Flush with running water for at least 20 minutes.

Hazards Identification

Inhalation
Vapors may cause dizziness or suffocation. May cause irritation or burns.
Skin
May cause irritation or burns.
Eyes
See Skin.
Hazards
Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapor explosion hazard indoors, outdoors or in sewers.
EC Risk Phrase
R 11 36/37/38
EC Safety Phrase
S 16 23 26 36
UN (DOT)
1993

Exposure Controls/Personal Protection

Personal Protection
Wear appropriate protective gloves, clothing and goggles.
Respirators
Wear positive pressure self-contained breathing apparatus (SCBA).

Fire Fighting Measures

Flash Point
10
Fire Fighting
Use of water spray when fighting fire may be inefficient. Small Fires: Dry chemical, carbon dioxide, water spray or alcohol-resistant foam. Large Fires: Water spray, fog or alcohol-resistant foam. Use water spray or fog; do not use straight streams.
Fire Potential
HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames.

Accidental Release Measures

Small spills/leaks
Make no contact with the spilled material. ELIMINATE all ignition sources and ground all equipment. Stop leak if you can do it without risk. A vapor suppressing foam may be used to reduce vapors. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. Use clean non-sparking tools to collect absorbed material.

Transport Information

UN Number
1993

Stability and Reactivity

Combustion Products
Fire may produce irritating, corrosive and/or toxic gases.