Home > 2-Allyloxyethanol > 2-Allyloxyethanol(111-45-5)
2-Allyloxyethanol(111-45-5)
Supplier Product Identification
Physical and Chemical Properties
First Aid Measures
Hazards Identification
Exposure Controls/Personal Protection
Fire Fighting Measures
Accidental Release Measures
Transport Information
Stability and Reactivity
Product Identification
Product Name
2-Allyloxyethanol
2-Allyloxyethanol
Synonyms
2-Allyloxyethanol
2-Prop-2-enoxyethanol
Allyl cellosolve
2-Allyloxyethanol
2-Prop-2-enoxyethanol
Allyl cellosolve
CAS
111-45-5
111-45-5
Formula
C5H10O2
C5H10O2
Molecular Weight
102.13
102.13
EINECS
203-871-7
203-871-7
RTECS
KJ5425000
KJ5425000
RTECS Class
Primary Irritant
Primary Irritant
Beilstein/Gmelin
1742145
1742145
Beilstein Reference
4-01-00-02388
4-01-00-02388
Physical and Chemical Properties
Boiling Point
98 - 99
98 - 99
Density
0.96095 g/cm3 (15 C)
0.96095 g/cm3 (15 C)
Refractive Index
1.44 (20 C)
1.44 (20 C)
First Aid Measures
Ingestion
Seek medical assistance.
Seek medical assistance.
Inhalation
Move victim to fresh air. Apply artificial respiration if victim is not breathing. Administer oxygen if breathing is difficult.
Move victim to fresh air. Apply artificial respiration if victim is not breathing. Administer oxygen if breathing is difficult.
Skin
Remove and isolate contaminated clothing and shoes. Wash skin with soap and water. Flush with running water for at least 20 minutes
Remove and isolate contaminated clothing and shoes. Wash skin with soap and water. Flush with running water for at least 20 minutes
Eyes
Flush with running water for at least 20 minutes.
Flush with running water for at least 20 minutes.
Hazards Identification
Inhalation
May cause irritation or burns.
May cause irritation or burns.
Skin
See Inhalation.
See Inhalation.
Eyes
See Inhalation.
See Inhalation.
Hazards
Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapor explosion hazard indoors, outdoors or in sewers.
Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapor explosion hazard indoors, outdoors or in sewers.
EC Risk Phrase
R 36/37/38
R 36/37/38
EC Safety Phrase
S 26 36
S 26 36
UN (DOT)
1987
1987
Exposure Controls/Personal Protection
Personal Protection
Wear appropriate protective gloves, clothing and goggles.
Wear appropriate protective gloves, clothing and goggles.
Respirators
Wear positive pressure self-contained breathing apparatus (SCBA).
Wear positive pressure self-contained breathing apparatus (SCBA).
Poison Class
4
4
Fire Fighting Measures
Flash Point
60
60
Fire Fighting
Use of water spray when fighting fire may be inefficient. Small Fires: Dry chemical, carbon dioxide, water spray or alcohol-resistant foam. Large Fires: Water spray, fog or alcohol-resistant foam. Use water spray or fog; do not use straight streams.
Use of water spray when fighting fire may be inefficient. Small Fires: Dry chemical, carbon dioxide, water spray or alcohol-resistant foam. Large Fires: Water spray, fog or alcohol-resistant foam. Use water spray or fog; do not use straight streams.
Fire Potential
HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames.
HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames.
Accidental Release Measures
Small spills/leaks
Make no contact with the spilled material. ELIMINATE all ignition sources and ground all equipment. Stop leak if you can do it without risk. A vapor suppressing foam may be used to reduce vapors. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. Use clean non-sparking tools to collect absorbed material.
Make no contact with the spilled material. ELIMINATE all ignition sources and ground all equipment. Stop leak if you can do it without risk. A vapor suppressing foam may be used to reduce vapors. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. Use clean non-sparking tools to collect absorbed material.
Transport Information
UN Number
1987
1987
Stability and Reactivity
Combustion Products
Fire may produce irritating, corrosive and/or toxic gases.
Fire may produce irritating, corrosive and/or toxic gases.
Contact
More
- Company Name:Hubei Xinjing New Material Co., Ltd
- Tel:027-83313147 15307111131
- Fax:027-88716711
- WebSite:https://www.chemicalbook.com/ShowSupplierProductsList525190/0.htm
- Company Name:wenzhou shoucheng
- Tel:15102776735 15102776735
- Fax:15102776735
- WebSite:https://wzschgkj.1688.com/page/index.html?spm=0.0.wp_pc_common_header_companyName_undefined.0
- Company Name:J & K SCIENTIFIC LTD.
- Tel:010-82848833 400-666-7788
- Fax:86-10-82849933
- WebSite:http://www.jkchemical.com
- Company Name:Meryer (Shanghai) Chemical Technology Co., Ltd.
- Tel:021-61259108 18621169109
- Fax:86-21-61259102
- WebSite:https://www.meryer.com/cn/index/
- Company Name:TCI (Shanghai) Development Co., Ltd.
- Tel:021-67121386
- Fax:021-67121385
- WebSite:https://www.tcichemicals.com/CN/zh/