Home > Trimethoxysilane > Trimethoxysilane(2487-90-3)
Trimethoxysilane(2487-90-3)
Supplier Product Identification
Physical and Chemical Properties
First Aid Measures
Handling and Storage
Hazards Identification
Exposure Controls/Personal Protection
Fire Fighting Measures
Accidental Release Measures
Stability and Reactivity
Transport Information
Product Identification
Product Name
Trimethoxysilane
Trimethoxysilane
Synonyms
Silane, trimethoxy-
Silane, trimethoxy-
CAS
2487-90-3
2487-90-3
Formula
C3H10O3Si
C3H10O3Si
Molecular Weight
122.22
122.22
EINECS
219-637-2
219-637-2
RTECS
VV6750000
VV6750000
RTECS Class
Primary Irritant
Primary Irritant
Beilstein/Gmelin
1697990
1697990
Beilstein Reference
4-01-00-01266
4-01-00-01266
Physical and Chemical Properties
Appearance
A colorless liquid.
A colorless liquid.
Solubility in water
Decomposes.
Decomposes.
Melting Point
-114.8
-114.8
Boiling Point
81 - 83
81 - 83
Vapor Pressure
76
76
Density
0.9601 g/cm3
0.9601 g/cm3
Heat Of Vaporization
36.77 kJ/mol
36.77 kJ/mol
Usage
Used to prepare a number of organic coupling agents utilized by the plastics industry as adhesion promotors.
Used to prepare a number of organic coupling agents utilized by the plastics industry as adhesion promotors.
Vapor Density
>1
>1
Refractive Index
1.359 (20 C)
1.359 (20 C)
First Aid Measures
Ingestion
Seek medical assistance.
Seek medical assistance.
Inhalation
Move patient to fresh air. Monitor for respiratory distress. If cough or difficulty breathing develops, evaluate for respiratory tract irritation, bronchitis, or pneumonitis. Administer oxygen and assist ventilation as required. Treat bronchospasm with beta2 agonist and corticosteroid aerosols.
Move patient to fresh air. Monitor for respiratory distress. If cough or difficulty breathing develops, evaluate for respiratory tract irritation, bronchitis, or pneumonitis. Administer oxygen and assist ventilation as required. Treat bronchospasm with beta2 agonist and corticosteroid aerosols.
Skin
Remove contaminated clothing and wash exposed area thoroughly with soap and water. A physician should examine the area if irritation or pain persists.
Remove contaminated clothing and wash exposed area thoroughly with soap and water. A physician should examine the area if irritation or pain persists.
Eyes
Irrigate exposed eyes with copious amounts of tepid water for at least 15 minutes. If irritation, pain, swelling, lacrimation, or photophobia persist, the patient should be seen in a health care facility.
Irrigate exposed eyes with copious amounts of tepid water for at least 15 minutes. If irritation, pain, swelling, lacrimation, or photophobia persist, the patient should be seen in a health care facility.
Handling and Storage
Storage
Keep in a cool, dry, dark location in a tightly sealed container or cylinder. Keep away from incompatible materials, ignition sources and untrained individuals. Secure and label area. Protect containers/cylinders from physical damage.
Keep in a cool, dry, dark location in a tightly sealed container or cylinder. Keep away from incompatible materials, ignition sources and untrained individuals. Secure and label area. Protect containers/cylinders from physical damage.
Handling
All chemicals should be considered hazardous. Avoid direct physical contact. Use appropriate, approved safety equipment. Untrained individuals should not handle this chemical or its container. Handling should occur in a chemical fume hood.
All chemicals should be considered hazardous. Avoid direct physical contact. Use appropriate, approved safety equipment. Untrained individuals should not handle this chemical or its container. Handling should occur in a chemical fume hood.
Hazards Identification
Ingestion
May cause toxic effects.
May cause toxic effects.
Inhalation
Respiratory tract irritation may be seen.
Respiratory tract irritation may be seen.
Skin
Contact with substance may cause severe burns.
Contact with substance may cause severe burns.
Eyes
See Skin.
See Skin.
Hazards
May be ignited by heat, sparks or flames. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapor explosion hazard indoors, outdoors or in sewers. May polymerize explosively when heated or involved in a fire. Runoff to sewer may create fire or explosion hazard. Containers may explode when heated. Many liquids are lighter than water.
May be ignited by heat, sparks or flames. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapor explosion hazard indoors, outdoors or in sewers. May polymerize explosively when heated or involved in a fire. Runoff to sewer may create fire or explosion hazard. Containers may explode when heated. Many liquids are lighter than water.
UN (DOT)
9269
9269
Exposure Controls/Personal Protection
Personal Protection
Wear appropriate protective gloves, clothing and goggles.
Wear appropriate protective gloves, clothing and goggles.
Respirators
Wear positive pressure self-contained breathing apparatus (SCBA).
Wear positive pressure self-contained breathing apparatus (SCBA).
Poison Class
5
5
Fire Fighting Measures
Flash Point
-4
-4
Fire Fighting
Use water in flooding quantities as fog. Use foam, dry chemical, or carbon dioxide. Keep run-off water out of sewers and water sources. Cool all affected containers with flooding quantities of water. Apply water from as far a distance as possible.
Use water in flooding quantities as fog. Use foam, dry chemical, or carbon dioxide. Keep run-off water out of sewers and water sources. Cool all affected containers with flooding quantities of water. Apply water from as far a distance as possible.
Fire Potential
Flammable/combustible material.
Flammable/combustible material.
Accidental Release Measures
Small spills/leaks
Keep sparks, flames, and other sources of ignition away. Keep material out of water sources and sewers. Build dikes to contain flow as necessary. Attempt to stop leak if without undue personnel hazard.
Keep sparks, flames, and other sources of ignition away. Keep material out of water sources and sewers. Build dikes to contain flow as necessary. Attempt to stop leak if without undue personnel hazard.
Stability and Reactivity
Stability
No data.
No data.
Combustion Products
Fire will produce irritating, corrosive and/or toxic gases.
Fire will produce irritating, corrosive and/or toxic gases.
Transport Information
UN Number
9269
9269
Hazard Class
6.1
6.1
Packing Group
I
I
Contact
More
- Company Name:Shanghai Kaisai Chemical Co., Ltd
- Tel:021-33516722 13701817765
- Fax:021-33516776
- WebSite:http://www.kaisaichem.com
- Company Name:J & K SCIENTIFIC LTD.
- Tel:010-82848833 400-666-7788
- Fax:86-10-82849933
- WebSite:http://www.jkchemical.com
- Company Name:Meryer (Shanghai) Chemical Technology Co., Ltd.
- Tel:021-61259108 18621169109
- Fax:86-21-61259102
- WebSite:https://www.meryer.com/cn/index/
- Company Name:TCI (Shanghai) Development Co., Ltd.
- Tel:021-67121386
- Fax:021-67121385
- WebSite:https://www.tcichemicals.com/CN/zh/
- Company Name:Beijing dtftchem Technology Co., Ltd.
- Tel:010-60275820 13031183356
- Fax:010-60270825
- WebSite:http://www.dtfchem.com