Home > 1,1,2,2-Tetrafluoroethyl methyl ether > 1,1,2,2-Tetrafluoroethyl methyl ether(425-88-7)
1,1,2,2-Tetrafluoroethyl methyl ether(425-88-7)
Supplier Product Identification
Physical and Chemical Properties
First Aid Measures
Hazards Identification
Exposure Controls/Personal Protection
Fire Fighting Measures
Accidental Release Measures
Transport Information
Stability and Reactivity
Product Identification
Product Name
1,1,2,2-Tetrafluoroethyl methyl ether
1,1,2,2-Tetrafluoroethyl methyl ether
Synonyms
1,1,2,2-Tetrafluoro-1-methoxyethane
1,1,2,2-Tetrafluoro-1-methoxyethane
CAS
425-88-7
425-88-7
Formula
C3H4F4O
C3H4F4O
Molecular Weight
132.06
132.06
EINECS
207-039-4
207-039-4
Beilstein/Gmelin
1737755
1737755
Beilstein Reference
4-02-00-00456
4-02-00-00456
Physical and Chemical Properties
Solubility in water
Soluble
Soluble
Melting Point
-107
-107
Boiling Point
33
33
Vapor Pressure
1300 (25 C)
1300 (25 C)
Density
1.2939 g/cm3 (20 C)
1.2939 g/cm3 (20 C)
Partition Coefficient
.91
.91
Heat Of Vaporization
24.8 kJ/mol
24.8 kJ/mol
Refractive Index
1.2939 (20 C)
1.2939 (20 C)
First Aid Measures
Ingestion
Seek medical assistance.
Seek medical assistance.
Inhalation
Move victim to fresh air. Apply artificial respiration if victim is not breathing. Administer oxygen if breathing is difficult.
Move victim to fresh air. Apply artificial respiration if victim is not breathing. Administer oxygen if breathing is difficult.
Skin
Remove and isolate contaminated clothing and shoes. Wash skin with soap and water. Flush with running water for at least 20 minutes
Remove and isolate contaminated clothing and shoes. Wash skin with soap and water. Flush with running water for at least 20 minutes
Eyes
Flush with running water for at least 20 minutes.
Flush with running water for at least 20 minutes.
Hazards Identification
Inhalation
May cause irritation or burns.
May cause irritation or burns.
Skin
See Inhalation.
See Inhalation.
Eyes
See Inhalation.
See Inhalation.
Hazards
Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapor explosion hazard indoors, outdoors or in sewers.
Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapor explosion hazard indoors, outdoors or in sewers.
EC Risk Phrase
R 11
R 11
EC Safety Phrase
S 16 23 29 33
S 16 23 29 33
UN (DOT)
3271
3271
Exposure Controls/Personal Protection
Personal Protection
Wear appropriate protective gloves, clothing and goggles.
Wear appropriate protective gloves, clothing and goggles.
Respirators
Wear positive pressure self-contained breathing apparatus (SCBA).
Wear positive pressure self-contained breathing apparatus (SCBA).
Fire Fighting Measures
Flash Point
-55
-55
Fire Fighting
Use of water spray when fighting fire may be inefficient. Small Fires: Dry chemical, carbon dioxide, water spray or alcohol-resistant foam. Large Fires: Water spray, fog or alcohol-resistant foam. Use water spray or fog; do not use straight streams.
Use of water spray when fighting fire may be inefficient. Small Fires: Dry chemical, carbon dioxide, water spray or alcohol-resistant foam. Large Fires: Water spray, fog or alcohol-resistant foam. Use water spray or fog; do not use straight streams.
Fire Potential
HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames.
HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames.
Accidental Release Measures
Small spills/leaks
Make no contact with the spilled material. ELIMINATE all ignition sources and ground all equipment. Stop leak if you can do it without risk. A vapor suppressing foam may be used to reduce vapors. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. Use clean non-sparking tools to collect absorbed material.
Make no contact with the spilled material. ELIMINATE all ignition sources and ground all equipment. Stop leak if you can do it without risk. A vapor suppressing foam may be used to reduce vapors. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. Use clean non-sparking tools to collect absorbed material.
Transport Information
UN Number
3271
3271
Stability and Reactivity
Combustion Products
Fire may produce irritating, corrosive and/or toxic gases.
Fire may produce irritating, corrosive and/or toxic gases.
Contact
More
- Company Name:Fuxin Ruifeng Fluorine Chemicals Co.,Ltd
- Tel:13941692605; 18741878758
- Fax:
- WebSite:http://www.fxrf.com.cn
- Company Name:Chongqing Xinfu Technology Co., Ltd
- Tel:023-72591919 15095802635
- Fax:
- WebSite:https://www.cnjf.com/aspx/ch/productList.aspx?classid=87
- Company Name:Shangfluoro
- Tel:021-65170832 17301729617
- Fax:
- WebSite:http://www.flonclean.com
- Company Name:J & K SCIENTIFIC LTD.
- Tel:010-82848833 400-666-7788
- Fax:86-10-82849933
- WebSite:http://www.jkchemical.com
- Company Name:Alfa Aesar
- Tel:400-6106006
- Fax:021-67582001/03/05
- WebSite:http://chemicals.thermofisher.cn