Supplier Product Identification Physical and Chemical Properties First Aid Measures Handling and Storage Exposure Controls/Personal Protection Fire Fighting Measures Accidental Release Measures Stability and Reactivity Hazards Identification
Home > Caproic acid propyl ester > Caproic acid propyl ester(626-77-7)

Caproic acid propyl ester(626-77-7)

Supplier Product Identification Physical and Chemical Properties First Aid Measures Handling and Storage Exposure Controls/Personal Protection Fire Fighting Measures Accidental Release Measures Stability and Reactivity Hazards Identification

Product Identification

Product Name
Caproic acid propyl ester
Synonyms
1-Propyl n-caproate
Hexanoic acid, propyl ester
Propyl caproate
CAS
626-77-7
Formula
C9H18O2
Molecular Weight
158.24
EINECS
210-963-0

Physical and Chemical Properties

Appearance
Colorless liquid with a fruity odor.
Solubility in water
Insoluble
Melting Point
-68.7
Boiling Point
187
Vapor Pressure
0.61 (25 C)
Density
0.867 g/cm3 (20 C)
Partition Coefficient
3.37
Heat Of Vaporization
42.4 kJ/mol
Vapor Density
5.4
Refractive Index
1.41

First Aid Measures

Ingestion
:DO NOT INDUCE VOMITING! Remove victim immediately from source of exposure. Provide rest, warmth and fresh air. Get medical attention.
Inhalation
Move the exposed person to fresh air at once. Get medical attention.
Skin
Remove affected person from source of contamination. Wash skin thoroughly with soap and water for several minutes. Get medical attention if any discomfort continues.
Eyes
Continue to rinse for at least 15 minutes. Get medical attention promptly if symptoms occur after washing.

Handling and Storage

Storage
Keep away from heat, sparks and open flame. Keep containers tightly closed. Keep in original container.

Exposure Controls/Personal Protection

Personal Protection
Wear splash-proof eye goggles, protective gloves and clothing.
Exposure Effects
Irritating to eyes, respiratory system and skin.

Fire Fighting Measures

Flash Point
52
Fire Fighting
Extinguish with foam or carbon dioxide. Avoid breathing fire vapors. Cool containers exposed to flames with water until well after the fire is out. Keep run-off water out of sewers and water sources. Dike for water control.

Accidental Release Measures

Small spills/leaks
Stop leak if possible without risk. Extinguish all ignition sources. Avoid sparks, flames, heat and smoking. Ventilate. Do not contaminate water sources or sewer. Absorb in vermiculite, dry sand or earth and place into containers. Wash thoroughly after dealing with a spillage.

Stability and Reactivity

Stability
Stable at normal temperatures and pressures.
Incompatibilities
Strong oxidizing agents.

Hazards Identification

EC Risk Phrase
R: 36/37/38
EC Safety Phrase
S: 26 36/37/39