General Description
A reddish-yellow fuming liquid with a pungent odor. Fumes are irritating to the eyes and mucous membranes. Solidifies at 37°F. Corrosive to metals and tissue. Used to make other chemicals, and in chemical analysis.
Reactivity Profile
Acidic salts, such as ANTIMONY PENTACHLORIDE, are generally soluble in water. The resulting solutions contain moderate concentrations of hydrogen ions and have pH's of less than 7.0. They react as acids to neutralize bases. These neutralizations generate heat, but less or far less than is generated by neutralization of inorganic acids, inorganic oxoacids, and carboxylic acid. They usually do not react as either oxidizing agents or reducing agents but such behavior is not impossible. Many of these compounds catalyze organic reactions.
Air & Water Reactions
Fumes in air to form hydrochloric acid. Reacts with water to yield heat and antimony pentaoxide (Sb2O5) and hydrochloric acid [Merck 11th ed. 1989].
Hazard
Corrosive, fumes in moist air, reacts
strongly with organics.
Health Hazard
Inhalation causes irritation of nose and throat. Contact of liquid with eyes or skin causes severe burns. Ingestion causes vomiting and severe burns of mouth and stomach. Overexposure by any route can cause bloody stools, slow pulse, low blood pressure, coma, convulsions, cardiac arrest.
Potential Exposure
It is used in dyeing, coloring metals
and in many organic chemical reactions as a catalyst.
Fire Hazard
Behavior in Fire: Irritating fumes of hydrogen chloride given off when water or foam is used to extinguish adjacent fire.
First aid
If this chemical gets into the eyes, remove any
contact lenses at once and irrigate immediately for at least
15 minutes, occasionally lifting upper and lower lids. Seek
medical attention immediately. If this chemical contacts
the skin, remove contaminated clothing and wash immediately
with soap and water. Seek medical attention immediately.
If this chemical has been inhaled, remove from
exposure, begin rescue breathing (using universal precautions,
including resuscitation mask) if breathing has
stopped and CPR if heart action has stopped. Transfer
promptly to a medical facility. When this chemical has
been swallowed, get medical attention. If victim is conscious,
administer water or milk. Do not induce vomiting.
Medical observation is recommended for 24 to 48 hours
after breathing overexposure, as pulmonary edema may be
delayed. As first aid for pulmonary edema, a doctor or authorized paramedic may consider administering a drug
or other inhalation therapy.
Shipping
UN1730 (liquid) Antimony pentachloride, liquid,
Hazard class: 8; Labels: 8-Corrosive material. UN1731
(solution) Antimony pentachloride, solutions, Hazard class:
8; Labels: 8-Corrosive material.
Incompatibilities
Decomposes on contact with heat, acids,
alkalis, ammonia, water or other forms of moisture producing
fumes of hydrogen chloride and antimony. Decomposes
above 77 C forming chlorine and antimony trichloride.
Attacks many metals in the presence of moisture forming
explosive hydrogen gas. Reacts with air forming corrosive
vapors.
Description
Antimony pentachloride is a noncombustible,colorless to reddish-yellow oily liquid with an offensive odor.Molecular weight= 299.05; Boiling point= 77℃ (decomposes); Freezing/Melting point= 3℃; Specific gravity(H2O:1)= 2.354 at 20℃; Liquid surface tension= (estimate) 50.015 N/m at 20℃; Latent heat of vaporization=1.60 3 105 J/kg; Heat of solution=2 4.925 3 105 J/kg;Vapor pressure: 0.84 mmHg at 20℃. Hazard Identification(based on NFPA-704 M Rating System): (solid or liquid)Health 3, Flammability 0, Reactivity 1. Decomposes on contact with water.
Chemical Properties
Antimony pentachloride is a noncombustible,
colorless to reddish-yellow oily liquid with an offensive
odor.
Chemical Properties
colourless to light yellow oily liquid
Waste Disposal
Encapsulate and transfer to an
approve landfill. If chemically treated and neutralized, the
chemical is amenable to biological treatment at municipal
sewage treatment plant. Consult with environmental regulatory
agencies for guidance on acceptable disposal practices.
Generators of waste containing this contaminant (≥100 kg/
mo) must conform with EPA regulations governing storage,
transportation, treatment, and waste disposal.
Physical properties
Antimony pentachloride is prepared by passing chlorine gas into molten antimony trichloride:
SbCl3 + Cl2 →SbCl5
or by the reaction of the element with excess chlorine:
2 Sb + 5 Cl2 → 2 SbCl5.
Uses
Antimony(V) chloride is used as a catalyst and an analytical reagent for testing alkaloids and cesium. It is also used as a polymerization catalyst as well as involved in the chlorination of organic compounds. It acts as a Lewis acid and a strong oxidizing agent.
Uses
As catalyst when replacing a fluorine substituent with chlorine in organic compounds.
storage
(1) Color Code—White: Corrosive or ContactHazard; Store separately in a corrosion-resistant location.(2) Color Code—Blue: Health Hazard/Poison: Store in asecure poison location. Prior to working with this chemicalyou should be trained on its proper handling and storage.Antimony pentachloride must be stored to avoid contactwith organic or combustible materials (such as wood,paper, and oil) since violent reactions occur. See incompatibilities. Store in tightly closed containers in a cool, wellventilated area away from water or moisture and heat.Sources of ignition, such as smoking and open flames, areprohibited where this chemical is used, handled, or storedin a manner that could create a potential fire or explosionhazard.