Supplier Product Identification Physical and Chemical Properties First Aid Measures Handling and Storage Hazards Identification Exposure Controls/Personal Protection Fire Fighting Measures Accidental Release Measures Stability and Reactivity
Home > Methyl 4-iodobenzoate > Methyl 4-iodobenzoate(619-44-3)

Methyl 4-iodobenzoate(619-44-3)

Supplier Product Identification Physical and Chemical Properties First Aid Measures Handling and Storage Hazards Identification Exposure Controls/Personal Protection Fire Fighting Measures Accidental Release Measures Stability and Reactivity

Product Identification

Product Name
Methyl 4-iodobenzoate
Synonyms
4-(Carbomethoxy)iodobenzene
4-(Methoxycarbonyl)phenyl iodide
4-Iodobenzoic acid methyl ester
Benzoic acid, 4-iodo-, methyl ester
Methyl p-iodobenzoate
p-(Methoxycarbonyl)phenyl iodide
CAS
619-44-3
Formula
C8H7IO2
Molecular Weight
262.04000000000002
EINECS
210-597-1
Beilstein/Gmelin
2208132
Beilstein Reference
4-09-00-01036

Physical and Chemical Properties

Appearance
Solid.
Solubility in water
Insoluble
Melting Point
112
Boiling Point
276
Vapor Pressure
0.005 (25 C)
Density
2.02 g/cm3 (10 C)
Partition Coefficient
3.4
Heat Of Vaporization
51.5 kJ/mol
Heat Of Combustion
-3866 kJ/mol
Vapor Density
9.03

First Aid Measures

Ingestion
If victim is conscious and alert, give 2-4 cupfuls of milk or water. Never give anything by mouth to an unconscious person. Get medical aid immediately.
Inhalation
Get medical aid immediately. Remove from exposure to fresh air immediately. If not breathing, give artificial respiration. If breathing is difficult, give oxygen.
Skin
Get medical aid. Flush skin with plenty of soap and water for at least 15 minutes while removing contaminated clothing and shoes. Wash clothing before reuse.
Eyes
Flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Get medical aid immediately.

Handling and Storage

Storage
Store in a cool, dry place. Keep container closed when not in use.
Handling
Wash thoroughly after handling. Remove contaminated clothing and wash before reuse. Avoid contact with eyes, skin, and clothing. Avoid ingestion and inhalation.

Hazards Identification

Ingestion
The toxicological properties of this substance have not been fully investigated. Causes gastrointestinal tract irritation.
Inhalation
Causes respiratory tract irritation. The toxicological properties of this substance have not been fully investigated.
Skin
Causes skin irritation. The toxicological properties of this material have not been fully investigated.
Eyes
Causes eye irritation. The toxicological properties of this material have not been fully investigated.

Exposure Controls/Personal Protection

Personal Protection
Eyes: Wear appropriate protective eyeglasses or chemical safety goggles as described by OSHA's eye and face protection regulations in 29 CFR 1910.133 or European Standard EN166. Skin: Wear appropriate protective gloves to prevent skin exposure. Clothing: Wear appropriate protective clothing to minimize contact with skin.
Respirators
A respiratory protection program that meets OSHA's 29 CFR 1910.134 and ANSI Z88.2 requirements or European Standard EN 149 must be followed whenever workplace conditions warrant a respirator's use.

Fire Fighting Measures

Flash Point
121
Fire Fighting
Wear a self-contained breathing apparatus in pressure-demand, MSHA/NIOSH (approved or equivalent), and full protective gear. During a fire, irritating and highly toxic gases may be generated by thermal decomposition or combustion. Extinguishing media: Use agent most appropriate to extinguish fire. In case of fire use water spray, dry chemical, carbon dioxide, or appropriate foam.

Accidental Release Measures

Small spills/leaks
Clean up spills immediately, using the appropriate protective equipment. Sweep up, then place into a suitable container for disposal. Avoid generating dusty conditions. Provide ventilation.

Stability and Reactivity

Incompatibilities
Oxidizing agents (strong, e.g. bromine, hydrogen peroxide, nitrogen dioxide, potassium nitrate).
Stability
Stable under normal temperatures and pressures.
Decomposition
Carbon monoxide, irritating and toxic fumes and gases, carbon dioxide, iodine.